Measuring wall thickness - CT wall thickness measurement

Non-destructive measurement of the wall thickness of components

We measure wall thicknesses of plastic, cast and metal components over the entire surface in 3D volume. Request precise wall thickness analysis by industrial CT from 3DIMETIK now.

Contact us without obligation and receive a solution proposal including an offer in max. 24 hours

Measuring wall thickness - CT wall thickness measurement

Non-destructive measurement of the wall thickness of components

We measure wall thicknesses of plastic, cast and metal components over the entire surface in 3D volume. Request precise wall thickness analysis by industrial CT from 3DIMETIK now.

Contact us without obligation and receive a solution proposal including an offer in max. 24 hours

3DIMETIK Managing Director

Have the wall thickness of components measured

As an accredited testing laboratory according to DIN EN ISO/IEC 17025 3DIMETIK is your nationwide contact for wall thickness measurement for components of all kinds.

We use industrial computer tomography to measure the wall thickness of your components. A measuring method that enables a non-destructive, full-surface and highly precise analysis of the wall thickness

Areas of application for a
wall thickness analysis

Check minimum wall thickness

[dsm_icon_list _builder_version="4.21.0" _module_preset="default" text_font_size="16px" background_enable_color="off" z_index="500" custom_margin="0px|||0px|false|false" custom_margin_tablet="0px|||0px|false|false" custom_margin_phone="29px||0px|0px|false|false" custom_margin_last_edited="on|phone" custom_padding="20px|20px|10px|20px|false|true" custom_padding_tablet="0px|20px|20px|20px|false|true" custom_padding_phone="0px|20px|0px|20px|false|true" custom_padding_last_edited="on|phone" border_radii="on|15px|15px|15px|15px" locked="off" global_colors_info="{}"][dsm_icon_list_child text="Ensure that defined minimum wall thicknesses are adhered to in order to guarantee stability and functionality." font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="18px" text_line_height="1.1em" tooltip_font_size="17px" tooltip_line_height="1.2em" global_colors_info="{}"][/dsm_icon_list_child][/dsm_icon_list]

Optimize component weight

[dsm_icon_list _builder_version="4.21.0" _module_preset="default" text_font_size="16px" background_enable_color="off" z_index="500" custom_margin="0px|||0px|false|false" custom_margin_tablet="0px|||0px|false|false" custom_margin_phone="29px||0px|0px|false|false" custom_margin_last_edited="on|phone" custom_padding="20px|20px|10px|20px|false|true" custom_padding_tablet="0px|20px|20px|20px|false|true" custom_padding_phone="0px|20px|0px|20px|false|true" custom_padding_last_edited="on|phone" border_radii="on|15px|15px|15px|15px" locked="off" global_colors_info="{}"][dsm_icon_list_child text="Reduce wall thicknesses in order to save material and weight without jeopardizing mechanical safety." font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="18px" text_line_height="1.1em" tooltip_font_size="17px" tooltip_line_height="1.2em" global_colors_info="{}"][/dsm_icon_list_child][/dsm_icon_list]

Analyze wall thickness profile

[dsm_icon_list _builder_version="4.21.0" _module_preset="default" text_font_size="16px" background_enable_color="off" z_index="500" custom_margin="0px|||0px|false|false" custom_margin_tablet="0px|||0px|false|false" custom_margin_phone="29px||0px|0px|false|false" custom_margin_last_edited="on|phone" custom_padding="20px|20px|10px|20px|false|true" custom_padding_tablet="0px|20px|20px|20px|false|true" custom_padding_phone="0px|20px|0px|20px|false|true" custom_padding_last_edited="on|phone" border_radii="on|15px|15px|15px|15px" locked="off" global_colors_info="{}"][dsm_icon_list_child text="Evaluate the complete course of the wall thickness in the component in three dimensions and visualize local deviations." font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="18px" text_line_height="1.1em" tooltip_font_size="17px" tooltip_line_height="1.2em" global_colors_info="{}"][/dsm_icon_list_child][/dsm_icon_list]

Evaluate breakthrough risks

[dsm_icon_list _builder_version="4.21.0" _module_preset="default" text_font_size="16px" background_enable_color="off" z_index="500" custom_margin="0px|||0px|false|false" custom_margin_tablet="0px|||0px|false|false" custom_margin_phone="29px||0px|0px|false|false" custom_margin_last_edited="on|phone" custom_padding="20px|20px|10px|20px|false|true" custom_padding_tablet="0px|20px|20px|20px|false|true" custom_padding_phone="0px|20px|0px|20px|false|true" custom_padding_last_edited="on|phone" border_radii="on|15px|15px|15px|15px" locked="off" global_colors_info="{}"][dsm_icon_list_child text="Identify critically thin areas that could lead to cracks or material breakthroughs under load." font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="18px" text_line_height="1.1em" tooltip_font_size="17px" tooltip_line_height="1.2em" global_colors_info="{}"][/dsm_icon_list_child][/dsm_icon_list]

Series monitoring
of wall thicknesses

[dsm_icon_list _builder_version="4.21.0" _module_preset="default" text_font_size="16px" background_enable_color="off" z_index="500" custom_margin="0px|||0px|false|false" custom_margin_tablet="0px|||0px|false|false" custom_margin_phone="29px||0px|0px|false|false" custom_margin_last_edited="on|phone" custom_padding="20px|20px|10px|20px|false|true" custom_padding_tablet="0px|20px|20px|20px|false|true" custom_padding_phone="0px|20px|0px|20px|false|true" custom_padding_last_edited="on|phone" border_radii="on|15px|15px|15px|15px" locked="off" global_colors_info="{}"][dsm_icon_list_child text="Systematically check wall thicknesses on several components to ensure consistent quality in series production." font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="18px" text_line_height="1.1em" tooltip_font_size="17px" tooltip_line_height="1.2em" global_colors_info="{}"][/dsm_icon_list_child][/dsm_icon_list]

Validate design

[dsm_icon_list _builder_version="4.21.0" _module_preset="default" text_font_size="16px" background_enable_color="off" z_index="500" custom_margin="0px|||0px|false|false" custom_margin_tablet="0px|||0px|false|false" custom_margin_phone="29px||0px|0px|false|false" custom_margin_last_edited="on|phone" custom_padding="20px|20px|10px|20px|false|true" custom_padding_tablet="0px|20px|20px|20px|false|true" custom_padding_phone="0px|20px|0px|20px|false|true" custom_padding_last_edited="on|phone" border_radii="on|15px|15px|15px|15px" locked="off" global_colors_info="{}"][dsm_icon_list_child text="Compare wall thicknesses in the prototype with the design data to ensure transferability to series production." font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="18px" text_line_height="1.1em" tooltip_font_size="17px" tooltip_line_height="1.2em" global_colors_info="{}"][/dsm_icon_list_child][/dsm_icon_list]

When you contact us, you will always speak directly to your contact person for industrial CT. No call center waiting loops, just competent measurement technicians.

How a wall thickness measurement works

Create CT scan & 3D volume model

First, the component is completely scanned using industrial computed tomography. This creates a high-resolution 3D solid model that digitally depicts the entire internal and external structure.

[dsm_icon_list _builder_version="4.21.0" _module_preset="default" text_font_size="16px" background_enable_color="off" z_index="500" custom_margin="14px|||-28px|false|false" custom_margin_tablet="0px|||0px|false|false" custom_margin_phone="29px||0px|0px|false|false" custom_margin_last_edited="on|phone" custom_padding="20px|20px|20px|20px|true|true" custom_padding_tablet="0px|20px|20px|20px|false|true" custom_padding_phone="0px|20px|0px|20px|false|true" custom_padding_last_edited="on|phone" border_radii="on|15px|15px|15px|15px" locked="off" global_colors_info="{}"][dsm_icon_list_child text="Non-destructive digitization of the component" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="18px" text_line_height="1.1em" tooltip_font_size="17px" tooltip_line_height="1.2em" global_colors_info="{}"][/dsm_icon_list_child][dsm_icon_list_child text="Detection of complex geometries and cavities" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="18px" text_line_height="1.1em" tooltip_font_size="17px" tooltip_line_height="1.2em" custom_margin="13px||||false|false" global_colors_info="{}"][/dsm_icon_list_child][dsm_icon_list_child text="High resolution for precise wall thickness analysis" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="18px" text_line_height="1.1em" tooltip_font_size="17px" tooltip_line_height="1.2em" custom_margin="13px||||false|false" global_colors_info="{}"][/dsm_icon_list_child][/dsm_icon_list]

Automatic wall thickness analysis in the 3D model

The wall thickness is calculated over the entire surface in the digital volume model. The software automatically determines minimum, maximum and average values.

[dsm_icon_list _builder_version="4.21.0" _module_preset="default" text_font_size="16px" background_enable_color="off" z_index="500" custom_margin="14px|||-28px|false|false" custom_margin_tablet="0px|||0px|false|false" custom_margin_phone="29px||0px|0px|false|false" custom_margin_last_edited="on|phone" custom_padding="20px|20px|20px|20px|true|true" custom_padding_tablet="0px|20px|20px|20px|false|true" custom_padding_phone="0px|20px|0px|20px|false|true" custom_padding_last_edited="on|phone" border_radii="on|15px|15px|15px|15px" locked="off" global_colors_info="{}"][dsm_icon_list_child text="Full-surface 3D wall thickness calculation" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="18px" text_line_height="1.1em" tooltip_font_size="17px" tooltip_line_height="1.2em" global_colors_info="{}"][/dsm_icon_list_child][dsm_icon_list_child text="Color-coded display of critical areas" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="18px" text_line_height="1.1em" tooltip_font_size="17px" tooltip_line_height="1.2em" custom_margin="13px||||false|false" global_colors_info="{}"][/dsm_icon_list_child][dsm_icon_list_child text="Identification of undercutting" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="18px" text_line_height="1.1em" tooltip_font_size="17px" tooltip_line_height="1.2em" custom_margin="13px||||false|false" global_colors_info="{}"][/dsm_icon_list_child][/dsm_icon_list]

Target/actual comparison and evaluation

Finally, the measured wall thickness can be compared with the CAD specifications. This makes design deviations or process-related wall thickness fluctuations visible.

[dsm_icon_list _builder_version="4.21.0" _module_preset="default" text_font_size="16px" background_enable_color="off" z_index="500" custom_margin="14px|||-28px|false|false" custom_margin_tablet="0px|||0px|false|false" custom_margin_phone="29px||0px|0px|false|false" custom_margin_last_edited="on|phone" custom_padding="20px|20px|20px|20px|true|true" custom_padding_tablet="0px|20px|20px|20px|false|true" custom_padding_phone="0px|20px|0px|20px|false|true" custom_padding_last_edited="on|phone" border_radii="on|15px|15px|15px|15px" locked="off" global_colors_info="{}"][dsm_icon_list_child text="Comparison with target geometry" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="18px" text_line_height="1.1em" tooltip_font_size="17px" tooltip_line_height="1.2em" global_colors_info="{}"][/dsm_icon_list_child][dsm_icon_list_child text="Evaluation of tolerance deviations" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="18px" text_line_height="1.1em" tooltip_font_size="17px" tooltip_line_height="1.2em" custom_margin="13px||||false|false" global_colors_info="{}"][/dsm_icon_list_child][dsm_icon_list_child text="Documentation in the test report" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="18px" text_line_height="1.1em" tooltip_font_size="17px" tooltip_line_height="1.2em" custom_margin="13px||||false|false" global_colors_info="{}"][/dsm_icon_list_child][/dsm_icon_list]

10 reasons to measure wall thickness with 3DIMETIK at

Advantages of industrial computed tomography
[dsm_icon_list _builder_version="4.21.0" _module_preset="default" text_font_size="16px" background_enable_color="off" z_index="500" custom_margin="30px|||-46px|false|false" custom_margin_tablet="0px|||0px|false|false" custom_margin_phone="12px|||0px|false|false" custom_margin_last_edited="on|phone" custom_padding="20px|20px|20px|20px|true|true" custom_padding_tablet="0px|20px|20px|20px|false|true" custom_padding_phone="0px|20px|22px|20px|false|true" custom_padding_last_edited="on|phone" border_radii="on|15px|15px|15px|15px" locked="off" global_colors_info="{}"][dsm_icon_list_child text="Non-destructive measurement without disassembly" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="18px" text_line_height="1.1em" tooltip_font_size="17px" tooltip_line_height="1.2em" global_colors_info="{}"][/dsm_icon_list_child][dsm_icon_list_child text="Full-surface 3D wall thickness analysis instead of point measurement" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="18px" text_line_height="1.1em" tooltip_font_size="17px" tooltip_line_height="1.2em" custom_margin="13px||||false|false" global_colors_info="{}"][/dsm_icon_list_child][dsm_icon_list_child text="Measurement of internal cavities possible" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="18px" text_line_height="1.1em" tooltip_font_size="17px" tooltip_line_height="1.2em" custom_margin="13px||||false|false" global_colors_info="{}"][/dsm_icon_list_child][dsm_icon_list_child text="Independent of component geometry and accessibility" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="18px" text_line_height="1.1em" tooltip_font_size="17px" tooltip_line_height="1.2em" custom_margin="13px||||false|false" global_colors_info="{}"][/dsm_icon_list_child][dsm_icon_list_child text="High measuring accuracy in the µm range" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="18px" text_line_height="1.1em" tooltip_font_size="17px" tooltip_line_height="1.2em" custom_margin="13px||||false|false" global_colors_info="{}"][/dsm_icon_list_child][dsm_icon_list_child text="Reproducible results for series testing" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="18px" text_line_height="1.1em" tooltip_font_size="17px" tooltip_line_height="1.2em" custom_margin="13px||||false|false" global_colors_info="{}"][/dsm_icon_list_child][dsm_icon_list_child text="Accredited test laboratory according to DIN EN ISO/IEC 17025" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="18px" text_line_height="1.1em" tooltip_font_size="17px" tooltip_line_height="1.2em" custom_margin="13px||||false|false" global_colors_info="{}"][/dsm_icon_list_child][dsm_icon_list_child text="Structured test reports with comprehensible documentation" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="18px" text_line_height="1.1em" tooltip_font_size="17px" tooltip_line_height="1.2em" custom_margin="13px||||false|false" global_colors_info="{}"][/dsm_icon_list_child][dsm_icon_list_child text="Germany-wide service with short lead times" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="18px" text_line_height="1.1em" tooltip_font_size="17px" tooltip_line_height="1.2em" custom_margin="13px||||false|false" global_colors_info="{}"][/dsm_icon_list_child][dsm_icon_list_child text="Framework agreements possible for larger volumes" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="18px" text_line_height="1.1em" tooltip_font_size="17px" tooltip_line_height="1.2em" custom_margin="13px||||false|false" global_colors_info="{}"][/dsm_icon_list_child][/dsm_icon_list]

When you contact us, you will always speak directly to an expert in 3D measurement technology. No call center waiting loops, just competent measurement technicians.

[dsm_image_carousel gallery_ids="11815,11816,11817,11818,11819,11820,11821,11822,11823,11824,11825,11826,11827,11829,11830,11831,11832,11833,11834,11835,11836,11837,11838,11840,11842,9859,11844,11846,11848,11849,11851,11853,11855" slide_to_show="8" pause_on_hover="on" arrows="off" dots="off" slide_to_show_tablet="8" slide_to_show_phone="4" slide_to_show_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" max_width_tablet="" max_width_phone="" max_width_last_edited="on|phone" custom_margin="-30px||20px||false|false" custom_padding="||0px||false|false" global_colors_info="{}"][/dsm_image_carousel]

References

What is evaluated when measuring wall thicknesses?

[dsm_icon_list _builder_version="4.21.0" _module_preset="default" text_font_size="16px" background_enable_color="off" z_index="500" custom_margin="0px|||-28px|false|false" custom_margin_tablet="0px|||0px|false|false" custom_margin_phone="29px||0px|0px|false|false" custom_margin_last_edited="on|phone" custom_padding="0px|20px|0px|20px|false|true" custom_padding_tablet="0px|20px|20px|20px|false|true" custom_padding_phone="0px|20px|0px|20px|false|true" custom_padding_last_edited="on|phone" border_radii="on|15px|15px|15px|15px" locked="off" global_colors_info="{}"][dsm_icon_list_child text="Minimum wall thickness in defined or critical areas" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="18px" text_line_height="1.1em" tooltip_font_size="17px" tooltip_line_height="1.2em" global_colors_info="{}"][/dsm_icon_list_child][dsm_icon_list_child text="Maximum wall thickness within the component" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="18px" text_line_height="1.1em" tooltip_font_size="17px" tooltip_line_height="1.2em" custom_margin="13px||||false|false" global_colors_info="{}"][/dsm_icon_list_child][dsm_icon_list_child text="Full-surface wall thickness profile in the 3D model" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="18px" text_line_height="1.1em" tooltip_font_size="17px" tooltip_line_height="1.2em" custom_margin="13px||||false|false" global_colors_info="{}"][/dsm_icon_list_child][dsm_icon_list_child text="Local weak points or underruns" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="18px" text_line_height="1.1em" tooltip_font_size="17px" tooltip_line_height="1.2em" custom_margin="13px||||false|false" global_colors_info="{}"][/dsm_icon_list_child][dsm_icon_list_child text="Deviation of the actual wall thickness from the CAD geometry" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="18px" text_line_height="1.1em" tooltip_font_size="17px" tooltip_line_height="1.2em" custom_margin="13px||||false|false" global_colors_info="{}"][/dsm_icon_list_child][dsm_icon_list_child text="Statistical evaluation for series tests" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="18px" text_line_height="1.1em" tooltip_font_size="17px" tooltip_line_height="1.2em" custom_margin="13px||||false|false" global_colors_info="{}"][/dsm_icon_list_child][/dsm_icon_list]
Advantages of shrinkage testing with industrial computed tomography

Years of 3D measurement technology
Experience

Successfully completed
projects

24 hours max. until you receive an offer

Individual or series testing
with 3DIMETIK

Individual testing of components with industrial computed tomography

Individual testing / project-related wall thickness analysis

The individual test is suitable for prototypes, initial sampling or specific questions in which the wall thickness of a particular component is to be precisely analyzed and documented.

[dsm_icon_list _builder_version="4.21.0" _module_preset="default" z_index="500" custom_margin="23px|||9px|false|false" custom_margin_tablet="0px|||21px|false|false" custom_margin_phone="0px|||0px|false|false" custom_margin_last_edited="off|desktop" custom_padding="|0px||0px|false|true" locked="off" global_colors_info="{}"][dsm_icon_list_child text="Wall thickness measurement of individual components in the CT test laboratory" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="16px" text_line_height="1.2em" tooltip_font_size="17px" tooltip_line_height="1.2em" text_font_size_tablet="18px" text_font_size_phone="14px" text_font_size_last_edited="on|phone" global_colors_info="{}"][/dsm_icon_list_child][dsm_icon_list_child text="Full-surface wall thickness analysis with color-coded display" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="16px" text_line_height="1.2em" tooltip_font_size="17px" tooltip_line_height="1.2em" custom_margin="15px||||false|false" text_font_size_tablet="18px" text_font_size_phone="14px" text_font_size_last_edited="on|phone" global_colors_info="{}"][/dsm_icon_list_child][dsm_icon_list_child text="Target/actual comparison with CAD geometry possible" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="16px" text_line_height="1.2em" tooltip_font_size="17px" tooltip_line_height="1.2em" custom_margin="15px||||false|false" text_font_size_tablet="18px" text_font_size_phone="14px" text_font_size_last_edited="on|phone" global_colors_info="{}"][/dsm_icon_list_child][dsm_icon_list_child text="Detailed test report including documentation" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="16px" text_line_height="1.2em" tooltip_font_size="17px" tooltip_line_height="1.2em" custom_margin="15px||||false|false" text_font_size_tablet="18px" text_font_size_phone="14px" text_font_size_last_edited="on|phone" global_colors_info="{}"][/dsm_icon_list_child][dsm_icon_list_child text="Short throughput times, optionally with express processing" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="16px" text_line_height="1.2em" tooltip_font_size="17px" tooltip_line_height="1.2em" custom_margin="15px||||false|false" text_font_size_tablet="18px" text_font_size_phone="14px" text_font_size_last_edited="on|phone" global_colors_info="{}"][/dsm_icon_list_child][/dsm_icon_list]
Series testing of components with industrial computed tomography

Series testing and framework agreements for larger volumes

Series testing under a framework agreement is ideal for recurring or larger quantities where wall thicknesses need to be systematically monitored and reproducibly evaluated.

[dsm_icon_list _builder_version="4.21.0" _module_preset="default" z_index="500" custom_margin="23px|||9px|false|false" custom_margin_tablet="0px|||21px|false|false" custom_margin_phone="0px|||0px|false|false" custom_margin_last_edited="off|desktop" custom_padding="|0px||0px|false|true" locked="off" global_colors_info="{}"][dsm_icon_list_child text="Defined measuring points or fully automated wall thickness analysis" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="16px" text_line_height="1.2em" tooltip_font_size="17px" tooltip_line_height="1.2em" text_font_size_tablet="18px" text_font_size_phone="14px" text_font_size_last_edited="on|phone" global_colors_info="{}"][/dsm_icon_list_child][dsm_icon_list_child text="Constant test parameters for reproducible results" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="16px" text_line_height="1.2em" tooltip_font_size="17px" tooltip_line_height="1.2em" custom_margin="15px||||false|false" text_font_size_tablet="18px" text_font_size_phone="14px" text_font_size_last_edited="on|phone" global_colors_info="{}"][/dsm_icon_list_child][dsm_icon_list_child text="Price advantages for larger scan volumes" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="16px" text_line_height="1.2em" tooltip_font_size="17px" tooltip_line_height="1.2em" custom_margin="15px||||false|false" text_font_size_tablet="18px" text_font_size_phone="14px" text_font_size_last_edited="on|phone" global_colors_info="{}"][/dsm_icon_list_child][dsm_icon_list_child text="Traceability and structured archiving of all results" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="16px" text_line_height="1.2em" tooltip_font_size="17px" tooltip_line_height="1.2em" custom_margin="15px||||false|false" text_font_size_tablet="18px" text_font_size_phone="14px" text_font_size_last_edited="on|phone" global_colors_info="{}"][/dsm_icon_list_child][dsm_icon_list_child text="Individual testing concepts agreed in the framework agreement" font_icon="||divi||400" icon_color="#8AB920" icon_padding="5px" icon_font_size="27px" icon_font_size_tablet="17px" icon_font_size_phone="28px" icon_font_size_last_edited="on|phone" _builder_version="4.21.0" _module_preset="default" text_text_color="#0A0000" text_font_size="16px" text_line_height="1.2em" tooltip_font_size="17px" tooltip_line_height="1.2em" custom_margin="15px||||false|false" text_font_size_tablet="18px" text_font_size_phone="14px" text_font_size_last_edited="on|phone" global_colors_info="{}"][/dsm_icon_list_child][/dsm_icon_list]

Frequently asked questions
for measuring wall thicknesses

[dsm_faq dsm_accordion_gap="25px" dsm_make_accordion_toggle="on" dsm_enable_schema_markup="on" dsm_close_bg_color="#ffffff" dsm_open_font_icon="N||divi||400" dsm_close_font_icon="C||divi||400" dsm_open_icon_color="#8B9881" dsm_close_icon_color="#8B9881" dsm_icon_placement="right" dsm_content_margin="10px||||false|false" _builder_version="4.21.0" _module_preset="default" header_font_size="19px" closed_header_font_size="17px" background_enable_color="off" global_colors_info="{}"][dsm_faq_child dsm_title="How accurate is a CT wall thickness measurement?" dsm_content="

The accuracy of CT wall thickness measurement depends on the component size, material and scan parameters and is typically in the micrometer range. Volumetric data acquisition creates a reproducible measurement basis for minimum wall thicknesses, tolerance analyses and series comparisons.

" dsm_open_icon_color="#373737" dsm_close_icon_color="#373737" _builder_version="4.21.0" _module_preset="default" header_item_level="h4" header_item_font_size="19px" closed_header_item_font_size="19px" closed_header_item_line_height="1.2em" background_color="#597482" background_enable_color="on" header_item_font_size_tablet="19px" header_item_font_size_phone="16px" header_item_font_size_last_edited="on|phone" closed_header_item_font_size_tablet="19px" closed_header_item_font_size_phone="16px" closed_header_item_font_size_last_edited="on|phone" border_radii="on|10px|10px|10px|10px" box_shadow_style="preset1" global_colors_info="{}" parentOrderClass="dsm_faq_0"][/dsm_faq_child][dsm_faq_child dsm_title="Can internal wall thicknesses be reliably determined?" dsm_content="

Internal wall thicknesses are fully recorded in the CT volume, as the component is digitally penetrated. This means that even concealed cavities, cooling channels or complex internal structures can be precisely analyzed without mechanically opening or destroying the component.

" dsm_open_icon_color="#373737" dsm_close_icon_color="#373737" _builder_version="4.21.0" _module_preset="default" header_item_level="h4" header_item_font_size="19px" closed_header_item_font_size="19px" closed_header_item_line_height="1.2em" background_color="#597482" background_enable_color="on" header_item_font_size_tablet="19px" header_item_font_size_phone="16px" header_item_font_size_last_edited="on|phone" closed_header_item_font_size_tablet="19px" closed_header_item_font_size_phone="16px" closed_header_item_font_size_last_edited="on|phone" border_radii="on|10px|10px|10px|10px" box_shadow_style="preset1" global_colors_info="{}" parentOrderClass="dsm_faq_0"][/dsm_faq_child][dsm_faq_child dsm_title="What is the difference between wall thickness and wall thickness?" dsm_content="

In technical terminology, wall thickness and wall thickness are used synonymously. Both terms describe the material thickness between the inner and outer surface of a component and are used to evaluate stability, load-bearing capacity and structural design.

" dsm_open_icon_color="#373737" dsm_close_icon_color="#373737" _builder_version="4.21.0" _module_preset="default" header_item_level="h4" header_item_font_size="19px" closed_header_item_font_size="19px" closed_header_item_line_height="1.2em" background_color="#597482" background_enable_color="on" header_item_font_size_tablet="19px" header_item_font_size_phone="16px" header_item_font_size_last_edited="on|phone" closed_header_item_font_size_tablet="19px" closed_header_item_font_size_phone="16px" closed_header_item_font_size_last_edited="on|phone" border_radii="on|10px|10px|10px|10px" box_shadow_style="preset1" global_colors_info="{}" parentOrderClass="dsm_faq_0"][/dsm_faq_child][dsm_faq_child dsm_title="Is a wall thickness analysis also suitable for series components?" dsm_content="

CT-based wall thickness analysis is suitable for both individual parts and series components. Using defined measurement parameters and automated evaluation, wall thicknesses can be systematically monitored and statistically evaluated to ensure process stability and quality.

" dsm_open_icon_color="#373737" dsm_close_icon_color="#373737" _builder_version="4.21.0" _module_preset="default" header_item_level="h4" header_item_font_size="19px" closed_header_item_font_size="19px" closed_header_item_line_height="1.2em" background_color="#597482" background_enable_color="on" header_item_font_size_tablet="19px" header_item_font_size_phone="16px" header_item_font_size_last_edited="on|phone" closed_header_item_font_size_tablet="19px" closed_header_item_font_size_phone="16px" closed_header_item_font_size_last_edited="on|phone" border_radii="on|10px|10px|10px|10px" box_shadow_style="preset1" global_colors_info="{}" parentOrderClass="dsm_faq_0"][/dsm_faq_child][/dsm_faq]

Contact us now without obligation

Data protection

12 + 11 =